Wednesday, July 25, 2012

NICE1000 Series Technical parameters Integrated Controller for Elevator Models


NICE1000 Series Integrated Controller for Elevator Models
 
System Models
Input Voltage
Power Capacity
KVA
Input Current (A)
Output Current
(A)
Appropriate Motor
(kW)
NICE-L-G/V-2002
Three Phase 220V
Range: -15%~20%
4.0
13.2
9.6
2.2
NICE-L-G/V-2003
5.9
17.0
15.6
3.7
NICE-L-G/V-4002
Three Phase 380V
Range: -15%~20%
4.0
6.5
5.1
2.2
NICE-L-G/V-4003
5.9
10.5
9.0
3.7
NICE-L-G/V-4005
8.9
14.8
13.0
5.5
NICE-L-G/V-4007
11.0
20.5
18.0
7.5
NICE-L-G/V-4011
17.0
29.0
27.0
11
NICE-L-G/V-4015
21.0
36.0
33.0
15
NICE-L-G/V-4018
24.0
41.0
39.0
18.5
NICE-L-G/V-4022
30.0
49.5
48.0
22
NICE-L-G/V-4030
40.0
62.0
60.0
30
 
The input voltage in the table above is for 220V products for three phase input application environments. If the input voltage is single phase, the power level should be increased one level. For instance, a NICE-L-G-2003 can be used for single phase 220V input driving a 2.2KW motor.
Technical Specifications
 
Category
Description/Specifications




Basic Specifications
Maximum Frequency
90Hz
Carrier Frequency
0.5kHz~16kHz; carrier frequency can be automatically adjusted according to load.
Motor Control Method
Open Loop Vector Control/Closed Loop Vector Control
Startup Torque
0.5Hz/180%(Open Loop Vector Control);
0Hz/200%(Closed Loop Vector Control)
0.5Hz/180% (SVC); 0Hz/200% (VC)
SpeedRange
1:100 (Open Loop Vector Control)(SVC)
1:1000 (Closed Loop Vector Control)(VC)
Speed Stabilizing Precision
±0.5%(Open Loop Vector Control)
(SVC)
±0.05%(Closed Loop Vector Control)
(VC)
Torque Control Precision
±5%(Closed Loop Vector Control)(VC)
Overload Capability
150% of rated current for 60s;200% of rated current for 1s
Motor Tuning
Asynchronous motors require static motor tuning; synchronous motors require initial angle tuning
Distance Control
Flexible adjustment of the direct stopping method of the leveling position.
Speed Up/Down Curve
N curve created automatically
Releveling
After there is a change in the carriage load, the flat bed will readjust.
Forced Speed Down
A new, dependable forced speed down capability automatically distinguishes the position of deceleration rack.
Shaft Automatic Learning
Uses 32-bit data, accurately recording the shaft position.
Leveling Adjustment
Capable of flexible, easy adjustment of flat bed.
Startup Torque Compensation
Personalized auto-learning weighing function.
Testing Capability
Easy method for application of multiple elevator debugging functions.
Malfunction Prevention
53 protection functions including short circuit check during motor electrification, I/O lack-phase protection, overcurrent protection, door malfunctions, coding protection.
Power-On Safety Self Test of Peripheral Devices
Performs safety checks on peripheral machines for grounding, short circuits, etc.
Status Monitoring
Assuring the regular operation of elevators based on the evaluation of response signals.
I/O Specifications
ON/OFF Input
24 ON/OFF input terminals, input specifications are 24V, 5mA
Analog Input
An expansion board provides analog input; input voltage range 0~10V
CommunicationsPort
An expansion board provides MODBUS communications
OutputPort
24 relay output terminal with functions that can be set
FloorI/O Port
26 Floor Button I/O terminal that can be set
Coded Disk Interface
Standard incremental coding device for open circuit collector output and SH-pull output.
Additional MCTC-PG-D divider card to be used with UVW coders.
Additional MCTC-PG-E divider card to be used with sine/cosine incremental coding devices.
Operation and Notices
Control Panel
5 LED display, showing performance parameters, operational speed, collecting main voltage, etc.
Small Keyboard
Shaft Auto-learning
Status Monitoring
Monitors all elevator parameters
Environment
Elevation
Lower than 1000m
Temperature
-10oC~+40oC (in temperatures of 40oC-50oC, please derate to use)
Humidity
Less than 95%RH; no condensation
Shock
Less than 5.9m/s2 (0.6g)
Storage Temperature
-20℃~+60℃


Inovance-Leading Frequency Inverter,Frequency Converter Drive China  Manufacturer

Specialized Drive for Elevator NICE1000 Overview


Input Voltage: Three Phase 220V, Three Phase 380V
Power Capacity (kVA): 4.0~40
Input Current (A): 13.2~62
Output Current (A): 9.6~60
Appropriate Motor (kW): 2.2~30
The NICE1000 is an independently developed integrated controller specifically for elevators designed by MCTC. Focusing on electronic systems in elevators, MCTC uses an entirely parallel signal transmission method, combining the advantages of high stability, ease of use and no need for adjustment that allow this perfect integration to be used in both private and cargo elevators.

Naming Rules


The structural code G is for NICE1000 integrated elevators with asynchronous motors. The structural code V is for NICE1000 integrated elevators with synchronous motors.